You are here: Home » Products » Drill/Saw » System 4300 » BJ4309 Reciprocating saw(System 4300)

PRODUCT CATEGORY

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

BJ4309 Reciprocating saw(System 4300)

Availability:
BJ4309 Reciprocating saw(System 4300)

Application :
For application in knee joint surgery and hip surgery operated by robot.
With the perfect shape of ergonomic design,whole unit is autoclavable,motor is imported,low noise, steadily and quickly cutting,no damage for soft tissue,long service life,be warranty for 2 years.


Specification:

Output power≥90w
Speed(r.p.m)/
Oscillations (osc/min)0-15000
Torque(Nm)/
Operation(V) voltage12
Sterilization155°C
Swings (°)/
Noise(db)≤70


Standard Configuration:
1. One handpiece
2. One battery
3. One charger
4. One saw blade.
5. One Aseptic battery transfer ring
6. One Operating manual
7. One Guarantee Card

Warranty:
The handpiece guarantees for 2 years, the battery and other fast consumption items guarantee for 3 months.


Advantages:
1.Our whole power tool can be autoclavable.
2.We can autoclavable for 135 °C (Improved type ≤ 155 °C ),with 1.6Mpa,in this way the bacilli and virus which can not killed bythe suffocating will be killed.
3.We use environment friendly nickel-metal hydride battery.
4.The machine has very low noise.
5.Our products has 2 years warranty period.


Notes:
1.Sterilize temperature ≤ 135 °C (Improved type ≤ 155 °C ),if the temperature is over 135 °C , the motor will be damaged.
2.Normal bone drill can only hold drill bits less than 6mm,acetabulum reaming drill with big torque,rpm is around 300,canulate drill is used with nail or K wire ,rpm is around 600.
3.The battery need to be get out of the power tool after surgery. Otherwise the small automatic discharge of the electric will make the life of the battery short.
4.The battery cannot be sterilized, it is not autoclavable.
5.The cranial bur must be washed right after the surgery by purger in order to avoid the blood stick in the bur, then we should make it dry.
6.The battery space in the handpiece of the tool should not have any water,after sterilization.
7.The cranial bur blade is made of medical stainless steel, in order to avoid broken, so it is flexible and not very hard, it is easy to be attrite,we suggest each blade only use for 1 surgery.


Previous: 
Next: 

QUICK LINKS

CONTACT US

  bojin6702@bojin-medical.com
  Floor 6,No.1313, Jiangchang Road, Jingan district, Shanghai, China

SEARCH PRODUCT

@ COPYRIGHT 2023, ALL RIGHTS RESERVED Shanghai Bojin Medical Instrument Co.,Ltd Support By inuox